This morning I installed a siren/speaker in the second floor hallway. It involved drilling a big hole in the wall and fishing out the wire. Now when the alarm is set, the Elk controller provides vocal feedback as well as an interior siren.Publish Post
Monday, September 17, 2007
Today I hooked up the motion detectors to the Elk controller. Earlier, I had purchased a component from Fry's to act as a bus bar so that I could wire up the motion detectors to the 12V output on the Elk controller.
I also had to add a 2.2K Ohm resistors in each of the motion detectors between the Normally Closed signal and the Common.
The Elk controller expects to see 2.2K Ohms on each of it's inputs in order to prevent someone from just shorting out the wires and circumventing the security system.
I also had to add a 2.2K Ohm resistors in each of the motion detectors between the Normally Closed signal and the Common.
The Elk controller expects to see 2.2K Ohms on each of it's inputs in order to prevent someone from just shorting out the wires and circumventing the security system.
Thursday, September 13, 2007
I checked continuity on the wire to the external horn this morning and installed the horn. Then I checked the wire to the keypad by the garage entrance and I installed the keypad with the flush mount kit. It was all very straightforward.
I programmed the names of some of the zones and set them all to DISABLED for now.
In the next couple of days I'll enable the motion detectors and then we should be able to set the alarm (and it will actually do something).
I programmed the names of some of the zones and set them all to DISABLED for now.In the next couple of days I'll enable the motion detectors and then we should be able to set the alarm (and it will actually do something).
Tuesday, September 11, 2007
Tuesday, June 5, 2007
Today I attached the Elk-M1XSP's to the structured wiring panel and plugged them into the Elk-M1DBH. I also built a Cat-5 wire for the Elk-M1XIN and plugged it into the Elk-M1DBH too.
I decided to locate the Aprilaire 8818 distribution panel on the wall, just below the wiring panel. I screwed it into the wall, leaving enough room for the Aprilaire 8811 protocol adapter which sits between the Elk-M1SXP and the 8818. While putting these components together, I realized that I need to purchase a power supply for the 8818 (why don't they ship the 8818 with a power supply!?!?). I connected the 8811 to the Elk-M1XSP with the DB-9 connector and cable supplied with the 8811.
When I had everything connected together, I powered on the Elk controller and asked it to search for devices on the RS-485 bus. It found all of the components I had hooked up. So far so good!
Monday, June 4, 2007
I picked up some cable fasteners from Fry's Electronics today. I used them to tidy up and secure the AC power cable for the Elk-M1Gold controller.
I also brought some 4-conductor wire, Cat-5 wire, RJ-45 plugs, and crimping tools with me and started connecting the various components together.
First, I connected the Elk-M1DBH to the Elk-M1Gold controller with the 4-conductor wire. The Elk-M1DBH sits on the RS-485 bus and acts like a hub.
Next, I built some Cat-5 cables to connect the Elk-M1DBH to the Elk-M1XSP's. I need to pick up some short #4 screws. I'll use them to attach the Elk-M1XSP circuit boards to their enclosures (without their covers) and then I'll use sticky tape to attach the enclosures to the structured wiring panel.
I configured one Elk-M1XSP to interface with the UPB lighting controls and set it to address #1 (device type 5). I configured the other Elk-M1XSP to interface with the Aprilaire thermostats and set it to address #2 (device type 5). I also configured the Elk-M1XIN to address #2 (device type 2 -- the Elk-M1Gold is address #1 by default).
From the M1G Installation and Programming manual:
I also brought some 4-conductor wire, Cat-5 wire, RJ-45 plugs, and crimping tools with me and started connecting the various components together.
First, I connected the Elk-M1DBH to the Elk-M1Gold controller with the 4-conductor wire. The Elk-M1DBH sits on the RS-485 bus and acts like a hub.
I configured one Elk-M1XSP to interface with the UPB lighting controls and set it to address #1 (device type 5). I configured the other Elk-M1XSP to interface with the Aprilaire thermostats and set it to address #2 (device type 5). I also configured the Elk-M1XIN to address #2 (device type 2 -- the Elk-M1Gold is address #1 by default).
From the M1G Installation and Programming manual:
Each data bus device is a specific "Device Type". Keypads are TYPE 1, Input (Zone) Expanders are TYPE 2, Output Expanders are TYPE 3, Serial Port Expanders are TYPE 5.... Every data bus device MUST have a unique "Address" setting within its type.